severity (ULONG)

      The severity of this error. Valid values are 1 (highest) through 6 (lowest):

    • SEVERITY1
      Critical: Condition from which there is no recovery.
    • SEVERITY2
      Major: Condition signifying that the loss of availability of a device or subproduct is imminent, or the performance of the device or subproduct has degraded to below an acceptable level.
    • SEVERITY3
      Minor: Condition that was recovered from after a number of attempts or a nonservice-affecting fault has occurred that should be corrected before a more serious error occurs.
    • SEVERITY4
      Warning: A potential error has been detected before any significant effects have been felt.
    • SEVERITY5
      Indeterminate: Condition where it is not possible to determine the severity of the error.
    • SEVERITY6
      Information

      For severity 1, 2 and 3, FFST will request trace information, if system trace is 'ON'. For severity 4, 5 and 6, FFST will not request trace information, unless the end user specifically requests it through a probe control table entry.


    [Back: FFSTPARMS Field - probe_ID]