Type
of query and options.
Values are as follows:
TYPE_CACHE_ONLY(0)
Returns information from the
protocol converter or port driver's cache only. Does not send anything to
the printer.
If the requested information is not available, ERROR_INFO_NOT_AVAIL is returned.
The caller should reissue the command with a different ulType value.
TYPE_SHORT_WAIT(1)
Returns
information via a communications channel with the printer that can be used
while a job is being sent to the printer.
An example would be using NPAP or SNMP. If the requested information cannot
be returned using this type of channel (for instance, if a PJL command is
required to get this information), ERROR_INFO_NOT_AVAIL is returned.
TYPE_LONG_WAIT(2)
Returns information using any necessary communications
channel with the printer, even if the request has to wait for the current
job being sent to the printer to complete.
If the printer supports only one command channel, and this channel can be
used while a job is being sent to the printer, TYPE_SHORT_WAIT(1) and TYPE_LONG_WAIT(2)
will behave in the same way.
TYPE_CACHE_UPDATE(3)
Returns information from the protocol converter
or port driver's cache and also update the cache in the background.
This is an optional type of query to support and, if it is not supported,
will return ERROR_INVALID_FUNCTION.
If the requested information is not available in the cache, ERROR_INFO_NOT_AVAIL
is returned. The caller should reissue the command with a different ulType
value.
TYPE_WITHOUT_WRAPPER(4)
Returns
passthru or alert information without any packet wrapper around it.
This is useful for BIDI_READ_PASSTHRU as it allows an application to send
and receive printer-interpreter language commands without having to know
the format of the BIDI protocol's data wrappers. An example would be removing
the NPAP wrapper before returning Postscript response data to an application.
If BIDI_READ_PASSTHRU is used without this value, the calling application
requests the data as the printer returns it, possibly with any data wrappers.
Note: If this value is used with any command other than BIDI_READ_PASSTHRU,
ERROR_INVALID_PARAMETER is returned.
TYPE_CACHE_WAIT(5)
Returns information from the protocol converter
or port driver's cache only. If the data is not available in the cache,
use any mechanism available to get the information.
If TYPE_CACHE_WAIT(5) is not be supported by the port driver or protocol
converter, ERROR_INVALID_PARAMETER is returned.
The value of TYPE_CACHE_WAIT(5) may be used by the print object to issue
BIDI_Q_STATUS, to get the current status of the printer without waiting
to communicate with the printer.
ulCommand (ULONG) - input
Generic
command code.
For all commands except BIDI_WAIT_ALERT and BIDI_Q_PORT, the BIDI protocol
converter may be called to generate protocol-specific command data to satisfy
query requests. See BIDI Command
Structures and Command Flow for contents of pInData and pOutData
for each of the following commands.
Current command values are as follows:
BIDI_READ_PASSTHRU(8001h)
BIDI_Q_PORT(800Bh)
Query BIDI capabilities of the port. See BIDI_Q_PORT(800Bh)
for input and output parameters.
BIDI_Q_SW(800Ch)
Query BIDI software capabilities. See BIDI_Q_SW(800Ch)
for input and output parameters.
BIDI_Q_DEVICE(800Dh)
BIDI_Q_INTERPRETER(800Eh)
BIDI_Q_INPUTBINS(800Fh)
BIDI_Q_OUTPUTBINS(8010h)
BIDI_Q_FONTS(8012h)
Query fonts for a particular interpreter. See BIDI_Q_FONTS(8012h)
for input and output parameters.
BIDI_Q_JOBS_COMPLETE(8013h)
BIDI_Q_JOBS_QUEUED(8014h)
BIDI_Q_STATUS(8015h)
BIDI_WAIT_ALERT(8016h
)
BIDI
_ Q _ JOBID ( 8017h )
BIDI
_ Q _ RESPONSE _ FMT ( 8018h )
BIDI
_ Q _ PORTDRV ( 8019h )
BIDI_Q_STORAGE(8023h)
0x0000B000
- 0x0000BFFF
Port-driver-specific commands.
pInData (PVOID) - input
cbInData (ULONG) - input
Length
of information in pInData, in bytes.
pOutData (PVOID) - output
Return
buffer.
Format of buffer depends on ulCommand. For BIDI_READ_PASSTHRU, this
will contain BIDI protocol-specific response data and will not be interpreted
by the BIDI protocol converter. However, if ulType is TYPE_WITHOUT_WRAPPER,
any protocol data wrapper is removed before returning the printer-specific
information.
For other commands, see BIDI
Command Structures and Command Flow for the structure returned.
pcbOutData (PULONG) - output
Points
to the length of the output buffer.
On entry, this is set to the length of the buffer passed in. On exit, it
is updated with the length of data available.
If ERROR_MORE_DATA(234) or NERR_BufTooSmall(2123) is set, this field has
the buffer size required to get all available information.
rc (ULONG) - returns
Return
codes.
- Success
- ERROR_INVALID_FUNCTION)
The command code
is not supported. This lack of support may occur if a new command is sent
to an old spooler, port driver, or protocol converter.
2(ERROR_FILE_NOT_FOUND)
The pszPortName given is not a valid port
name configured for this port driver.
5(ERROR_ACCESS_DENIED)
Not authorized to access printer port.
8(ERROR_NOT_ENOUGH_MEMORY)
Not enough memory to satisfy request.
29(ERROR_WRITE_FAULT)
Failure attempting to write to the device. The
printer might not have received the query request.
87(ERROR_INVALID_PARAMETER)
An invalid parameter was specified; most likely
an invalid buffer pointer was given.
211(ERROR_INFO_NOT_AVAIL)
The requested information is not available in the
protocol converter cache, or the request cannot be sent with the given ulType
value. The request should be reissued with a different ulType value.
234(ERROR_MORE_DATA)
Part
of the information requested was returned, but there was not enough room
for all the data. *pcbOutData contains the size of buffer needed
to retrieve all the query response data.
640(ERROR_TIMEOUT)
The printer response was not received within the
time allotted. The caller may reissue the query, at which time the information
might be available.
683(ERROR_BIDI_NO_SUPPORT)
The
printer is not in bidirectional mode, therefore query requests are not honored.
The port also may be in the process of being shut down.
2123(NERR_BufTooSmall)
No
information was returned because the output buffer was too small. *pcbOutData
contains the size of buffer needed to retrieve all the query response
data.
0x4005(PMERR_SPL_INV_HSPL)
Not
currently in a passthru session.
0x4011(PMERR_SPL_INV_JOB_ID)
No job is being actively sent to the printer port,
therefore BIDI_Q_JOBID is not successful.
0x4041(PMERR_SPL_SESSION_TERM)
The passthru session has been terminated.
0x403D(PMERR_SPL_CNV_NOT_INIT)
The protocol converter or port driver has not been
initialized for this port.
0x403F(PMERR_SPL_TYPE_NOT_AVAIL)
The storage type requested for BIDI_Q_FONTS or
BIDI_Q_STORAGE is not available in the printer.
[Back: SplPdQuery Return Value - rc]