The CD-ROM Device Manager will initialize the block length to 2048 bytes per sector. When the Device Manager receives a Readlong IOCtl request (Category 80h, Function 72h), it will issue a Mode Select to change the block length to either 2340 or 2352 bytes, depending on the maximum block length the drive supports. The CD-ROM Device Manager will only issue the Mode Select command to change the block length if the current block length does not match the requested block length.

Prior to the first Read Long IOCtl command, the CD-ROM Device Manager will issue a set of Mode Select commands with various block length values to determine the maximum block length the drive supports. If the Adapter Device Driver receives a Mode Select command with a Block Length value which is not supported, it should return an error with a Sense Key of 05h (Illegal Request) and the Additional Sense Code set to 26h (Invalid field in parameter list).

If the drive can only read a maximum of 2340 bytes per sector, the CD-ROM Device Manager will append 12 bytes of zeros (where the sync bytes are normally placed) to each sector after the read completes. This will ensure a complete 2352 byte sector is always returned back to the application when a ReadLong IOCtl command is issued.