The SCB commands relieve the system of transferring command blocks to the adapter through programmed input and output. The SCB specifies the desired command and associated parameters. An SCB must begin on a doubleword boundary, and any address translations, from virtual to physical, must be performed by system software before the SCB pointer is loaded into the command interface registers. If 80386 virtual page mode is being used, system software must also ensure that the SCB, data buffers, and termination status block (TSB) areas are locked into memory. The SCB specifies the desired command and associated parameters. When the SCB (or chain of SCBs) has been performed by the adapter, an interrupt request is issued to the system. The adapter presents only one interrupt request at a time to the system.

The following figure shows the format of the subsystem control block as it applies to device-related commands.

ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
15  14  13  12  11  10  9  8  7  6  5  4  3  2  1  0     Remarks

<---- Command Dependent ---> ND NS C5 C4 C3 C2 C1 C0     Command Word
RD  ES  RE  PT   0  SS  BB 0  0  0  0  0  0  0  0 CH     Enable Word
<------------ Least Significant Word -------------->     Logical Block
<------------ Most Significant Word --------------->      Address
<------------ Least Significant Word -------------->     System Buffer
<------------ Most Significant Word --------------->      Address
<------------ Least Significant Word -------------->     System Buffer
<------------ Most Significant Word --------------->      Byte Count
<------------ Least Significant Word -------------->     Termination Status
<------------ Most Significant Word --------------->      Block Address
<------------ Least Significant Word -------------->     Optional SCB Chain
<------------ Most Significant Word --------------->      Address
<------------ Number of Blocks -------------------->     Block Count
<------------ Block Size -------------------------->     Block Length
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ

A command is encoded in the first word of the SCB. The setting of bits 15 - 8 of the first word depends on the specific command identified in bits 5 - 0. If bit 7 (ND) of this word is set to 1, the adapter will not disconnect the target device during command execution. If bit 6 (NS) of this word is set to 1, the adapter will not send any Synchronous Data Transfer Request messages to the target device.

The second word of the SCB is used to enable options that are used to modify a specified command, as shown in the following table.

ÚÄÄÄÄÄÄÂÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³Bit   ³Symbol³Function                                          ³
ÃÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³15    ³RD    ³Input/Output Control                              ³
ÃÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³14    ³ES    ³Report TSB Status Only on Error                   ³
ÃÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³13    ³RE    ³Retry Enable                                      ³
ÃÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³12    ³PT    ³Pointer to List                                   ³
ÃÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³10    ³SS    ³Suppress Exception Short                          ³
ÃÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³9     ³BB    ³Bypass Buffer                                     ³
ÃÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³8 - 1 ³      ³Reserved                                          ³
ÃÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³0     ³CH    ³Chain on No Error                                 ³
ÃÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³      ³      ³                                                  ³